The myDatalogC3 enables data acquisition, communication and control in the control cabinet. The data will be transferred to the platform. Basic software is available for the application logic. The device is configured via the graphical, user-friendly interface. Alternatively, you can program your own applications and customise myDatalogC3 to suit your needs.
PLC, router, firewall and data transmission to the web platform are integrated in myDatalogC3. This ensures secure data transmission and protects information from unauthorized access. Due to the coordinated overall system, process-related requirements are already implemented and the integration of the solution is minimal.
The channels and alarm thresholds are easily configured via the graphical interface on the platform. In addition, you benefit from evaluation and reporting functions. To customize the application to your specific requirements, programming with extensive libraries is possible in the studio.
The interfaces are remotely configurable (universal input (4-20mA), RS232, RS485, CAN). This ensures the greatest flexibility. The device is perfectly applicable in automation, control and remote action. The two relays are individually configurable. Sensors are integrated in a few minutes.
With the input extension myDatalogC3e 12UI/2Rel the base unit gets additional twelve universal inputs as well as two potential-free switch contacts for controlling actuators. The output extension myDatalogC3e 3mA/6Rel expands by three analog outputs and six relays.
Remotely configure, control and evaluate
With the pre-installed software, the basic functionalities are parameterized user-friendly and graphically on the platform. Basic functions of the software for myDatalogC3 (optional with extension modules):
Central management
The platform allows you to create alerts, dashboards and reports within minutes. Updates to firmware, applications and configurations are conveniently carried out remotely via the web login – without having to travel to the unit. Integration into further systems is easily possible via the web interfaces (RESTful API or OPC-UA). This allows, for example, a direct coupling into process control systems.
Modbus RTU/ASCII
The Modbus master library currently supports the master mode for serial interfaces (RS232 and RS485) and is characterised by its universal applicability. In addition, great importance was attached to easy integration into own projects during the development. Zudem steht der vollständige Sourcecode im Studio zur Verfügung. The data transmission can be carried out either in the efficient Modbus-RTU or alternatively in the Modbus-ASCII format. You can find out more here. Upcoming: Standard software for Modbus configuration. Ask your Partner Manager for more details.
Save costs, contribute to sustainability
Rely on state-of-the-art data loggers and sensors to develop innovative solutions for comprehensive energy monitoring and management. Track and optimise your energy consumption to reduce costs and promote sustainability. With real-time monitoring and detailed analysis, you can stay on top of things and respond to changes immediately. This makes your energy management not only more efficient, but also future-proof.
With the help of the runtime calculator, you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.
myDatalogC32x | myDatalogC33x | |
---|---|---|
Distinguishing features | Standard applications with 3 MB flash memory | Data storage (512 MB Flash, 8 MB RAM, 128 kb FRAM) Additional connectivity via WiFi a network port |
Item no. | The variants differ in terms of data transmission 301293 LTE-M1/NB1 301629 2G/4G World |
301331 WiFi/2G/3G/4G World |
Inputs | 3x analogue or digital and 12x analogue or digital (input extention) |
|
Input configuration |
|
|
Measuring range / resolution |
|
|
Temperature sensor | ||
Internal sensors and measured values |
|
|
Serial interfaces, bus interfaces |
|
|
Outputs |
|
|
Power supply | 9...32VDC | |
Protection class | IP20 / IP40 (connection area / actuation area) | |
Display | RGB-LED | |
Dimensions | 70 x 92 x 63mm (without antenna), 4DU | |
Data transmission | Optional:
|
WiFi/2G/3G/4G |
Name | Hardware Version | Document Category | Revision | |
---|---|---|---|---|
Fact Sheet myDatalogC32x M1/NB1 EU | from Hw 1.2 | Fact Sheet | 05 | |
Fact Sheet myDatalogC33x WIFI/2G/3G/4G World | from Hw 1.2 | Fact Sheet | 05 | |
Manual myDatalogC32x | from Hw 1.2 from Hw 1.7 |
Manual | 07 | |
Manual myDatalogC33x | from Hw 1.2 | Manual | 07 | |
EU Declaration of Conformity myDatalogC32x M1/NB1 EU | from Hw 1.2 | EU Declaration of Conformity | 22.09.2023 | |
EU Declaration of Conformity myDatalogC3xx WIFI/2G/3G/4G World | from Hw 1.2 | EU Declaration of Conformity | 22.09.2023 | |
3D View myDatalogC3xx | from Hw 1.2 | 3D View | Hw 1.2 |
Spannung AC | Spannung DC | Strom AC | Strom DC | Bemessungsstoßspannung | ||
---|---|---|---|---|---|---|
myDatalogC3 | Relay Mode | 32V | 32V | 2A | 2A | 1.5kV |
Impuls Mode | 32V | 32V | 0,13A | 0,13A | ||
Input extension | Relay Mode | 230V | 220V | 2A | 2A | |
Impuls Mode | 230V | 230V | 0,13A | 0,13A | ||
Output extension | Relay Mode | 230V | 30V | 3A / 6A relay for common CC | 3A / 6A relay for common CC | 2.5kV |
Producttitle | myDatalogC3 |
---|---|
Item no. | myDatalogC3 |
Power supply | 9...32VDC, from 0.9W, nominal 5W |
Data memory | myDatalogC32x:
|
Programming | In Studio with C-like scripting language built on PAWN |
Dimensions | 70 x 92 x 63mm (without antenna) |
Protection class | IP20 / IP40 (connection area/operating area) |
Operating temperature | -20...+60°C |
Inputs | 3 x analogue or digital (individually configurable per channel)
|
Resolution |
|
Outputs | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) |
Serial interfaces | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) |
Data transmission | myDatalogC32x:
|
SIM | integrated SIM chip |
Positioning | by using GSM cell location |
base price | - |
Fill in the form below and give us a rough idea of your application. We will be happy to provide you with a non-binding quotation.
Microtronics Engineering GmbH
Hauptstrasse 7
3244 Ruprechtshofen
Austria
Microtronics Engineering GmbH
Hauptstrasse 7
3244 Ruprechtshofen
Austria
In order to use our live chat, you must agree to the loading of Hubspot cookies. You can find out more about this in our privacy policy.