myDatalog

Robust data logger for measuring and transmitting in the ATEX zone

The myDatalog records the data from up to four remote pressure and radar sensors for level measurement (additional sensors on request). A 4-20 mA input with switchable and adjustable sensor supply (from 0.1 seconds; 0..22V) is optionally available. The data is transmitted via mobile radio (LTE-M). The robust system is suitable for use in ATEX Zone 1.

Applications:

  • Stormwater overflow basin
  • Combined sewer
  • Indirect Discharge Controller
  • Level measurement
  • Flow measurement for billing

 

10-year runtime with ultra low power technology

The myDatalog has an impressive runtime of 10 years (with a 10-second measuring interval and daily data transmission via cellular). If a sensor is supplied via the mA input, a running time of seven years is achieved (with 5 min measuring interval, 1 sec warm-up and 24 h transmission interval).

myDatalog und myDatasens werden in der ATEX Zone 1 eingesetzt

ATEX Zone 1

The myDatalog is certified for use in the hazardous environment. The data is transmitted via cellular directly from ATEX zone 1 ( II 2G Ex ib IIB T3 Gb) to the integrated online platform.

OLED Display from myDatalog and myDatasens

OLED color display

The current measured values and relevant status information can be viewed directly on the myDatalog on the 1.5" full color OLED display.

Querstreben Montagesetz im Einsatz

Measure every 10 seconds | 10 years runtime

The sensors measure every 10 seconds and transmit the data daily via cellular. The measuring system works maintenance-free for 10 years. If a limit value is exceeded, the data logger transmits immediately and triggers an alarm.

YouTube

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren

Video laden

Webinar

Data from the sewer - configure level measurement quickly and easily with just 3 components

In the video, we go down into the sewer together and have a look at the combination of a radar sensor and a mA sensor. This enables numerous applications, such as level measurement and alarming or control during heavy rainfall events.

Sabrina Waldbauer and Simon Somers present the innovations in the “myDatasens+” IoT app. Up to four sensors (radar or pressure sensors) are easily configured via the platform interface.

Level measurement of fresh, gray and waste water

Pressure and radar sensor

The device detects a remote sensor in the ATEX zone and transmits the measured values to the platform. Configuration is also performed via the platform.

  • Radar sensor
    With the radar sensor, you will never miss an event in the channel again. The sensor is mounted wirelessly in the duct. The enormously low energy consumption leads to a runtime of up to 10 years. The mounting bracket and the spirit level directly on the radar sensor make installation easier and maximise measurement precision.
  • Pressure sensor myDatalogGauge
    It is possible to create base point tables for special container geometries with trigger and alarm functionalities.
    Parameterisation (offset and trim) takes place via the platform.

myDatalog with sensor supply

Supply, record and transmit 4-20mA sensors in ATEX zone

The mA input on the myDatalog can be used to supply 4-20 mA sensors directly in ATEX Zone 1 ( II 2G Ex ib IIB T3 Gb). The device feeds up to 22V into the 4-20mA loop. Sensors have already been tested for compatibility for the myDatalogue and a corresponding intrinsic safety certificate has been created.

  • Digital end position sensor REP01-15
    Detect the end position of throttles, gate valves or cover openings
  • Hydrolevel® sensor of the SPK series
  • Radar level sensor Micropilot FMR20
  • Radar sensor Vegapuls C21
  • Hydrostatic level transmitter Waterpilot FMX21
  • Tilt Measuring System NM1-2L-420-ATEX
  • Pressure transmitter Cerabar PMC51B

Other sensors are available on request.

Product configurator

With the help of the runtime calculator, you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.

Technical data

Product title myDatalog
Item no. 301037 / 301266 / 300868 / 301267
Inputs 4x remote sensors and 1x analogue (option)
Input configuration 0...20mA / 4...20mA
Measuring range / resolution 0...20mA / 4...20mA: 6.3µA, load: 4Ω
Sensor supply 1 x switchable and adjustable sensor supply from 0.1 seconds Range 0...22V
Temperature sensor -20...+50°C
Internal sensors and measured values
  • SOC (state of charge)
  • Battery life in days
  • Mobile strength
  • Humidity and temperature in the device
Power supply Internal battery 2x Li-SOCl2 (D-cell)
Battery life time
  • Battery life 10 years with remote sensor at 10sec measuring interval and 24h data transmission
  • Battery life 7 years with 4-20 mA sensor with 1sec warm-up time at 5min measuring interval and 24h data transmission
Protection class IP66 / IP68 / IP69 (IP68: 105days@1m)
Ex certification Zone 1 ( II 2G Ex ib IIB T3 Gb)
Display 1.5" Full Color Display
Dimensions 106 x 169 x 61 mm (with protective armour)
Data transmission LTE-M/NB-IoT Modem (World)
Name Hardware Version Document Category Revision
Fact Sheet myDatalogGauge 3G Zone 1 from Hw 3.0 Fact Sheet 01
Fact Sheet myDatalogEx LTE-M Zone 1 from Hw 5.0 Fact Sheet 05
Fact Sheet myDatalogGauge LTE-M Zone 1 from Hw 5.0 Fact Sheet 02
Manual myDatalogEx Zone 1 from Hw 2.0 Manual 5
Manual myDatalogEx LTE-M Zone 1 from Hw 5.0 Manual 08
Manual myDatalogGauge 3G Zone 1 from Hw 3.0 Manual 02
Manual myDatalogGauge LTE-M Zone 1 from Hw 5.0 Manual 03
Manual myDatasensBLE+ installed on myDatalogEx LTE-M from Hw 5.2 Manual 01
Manual myDatasensBLE+ installed on BLE & LTE-M Gateway ATEX from Hw 5.0 Manual 01
Manual myDatalog D012-x1009200D05 / Spillover Pro Analog from Hw 1.0 Manual 04
Manual myDatalog D013-x1009200C05 / Spillover Pro GW from Hw 1.0 Manual 04
EU Declaration of Conformity BLE Gauge Zone 1 from Hw 2.0 EU Declaration of Conformity 18.01.2021
EU Declaration of Conformity BLE 3G Gateway ATEX Zone 1, myDatalogGauge, myDatasensH2S1000 from Hw 3.0 EU Declaration of Conformity 11.11.2021
EU Declaration of Conformity BLE Gateway ATEX Zone 1 from Hw 3.0 EU Declaration of Conformity 11.11.2021
EU Declaration of Conformity myDatalogEx Zone 1 from Hw 2.0 EU Declaration of Conformity 18.01.2021
EU Declaration of Conformity myDatalogEx LTE-M Zone 1 from Hw 5.0 EU Declaration of Conformity 22.06.2023
EU Declaration of Conformity BLE LTE-M Gateway ATEX Zone 1 from Hw 5.0 EU Declaration of Conformity 22.06.2023
EU Type Examination Certificate BLE Gauge Zone 1 from Hw 2.0 EU Type Examination Certificate 21.11.2019
EU Type Examination Certificate (BLE Gateway ATEX, BLE & 3G Gateway ATEX) from Hw 2.0 EU Type Examination Certificate 06.09.2017
EU type examination certificate (BLE Gateway, BLE 3G Gateway, myDatalogGauge, my Datasens) ATEX 1st amendment from Hw 3.0 EU type-examination certificate
1st supplement
27.10.2021
EU Type Examination Certificate myDatalogEx Zone 1 from Hw 2.0 EU Type Examination Certificate 01.10.2020
EU Type Examination Certificate myDatalogEx Zone 1 1st Supplement from Hw 3.0 EU type-examination certificate
1. supplement
27.10.2021
EU Type Examination Certificate myDatalogEX LTE-M Zone1 2nd supplement from Hw 5.0 EU type-examination certificate
2nd supplement
21.04.2023
EU Type Examination Certificate BLE & LTE-M Gateway Zone 1 2nd Supplement from Hw 5.0 EU type-examination certificate
2nd supplement
21.07.2023
Proof of intrinsic safety Pressure transmitter Cerabar PMC51B for myDatalogEx from Hw 2.0 Proof of intrinsic safety 01v002
3D View BLE & LTE-M Gateway from Hw 1.0 3D View Hw 1.0
3D View myDatalogEx Zone 1 from Hw 1.0 3D View Hw 1.0

Get a free quote

In order to use our live chat, you must agree to the loading of Hubspot cookies. You can find out more about this in our privacy policy.