myDatasens

Gas monitoring: Live gas measurement of H2S, NH3 & H2O2

The portable, robust myDatasens data logger measures and transmits live gas concentrations (HS, NH or HO) in the ambient air.

 

The measuring device is available with a variety of sensors.

Robust and resistant

The myDatasens' rubber armour is specially designed for use in harsh environments (IP66/IP68/IP69). Korrosive Gase, Wasser und Staub können dem Gerät nichts anhaben. Cost-effective replacement parts and above-average battery life optimise cost-efficient operation.

myDatasens - Measuring device for measuring and transmitting gas values in the ATEX zone

Certified for ATEX Zone 1

myDatasens devices are certified for use in ATEX Zone 1. The data is transmitted directly from the potentially explosive atmosphere.

myDatasensH2S colour display

Full color display

The 1.5" full color OLED display shows the remaining days to the next service / calibration directly on site at the measuring point. In addition, the GSM field strength, the battery charge status, the serial number and the current measured values are visible.

H2S Device

Battery life up to 10 years

With a live gas measurement (measurement interval 1 second) the battery life is up to 6 years. If the measuring interval is increased to one minute and the measured values are transmitted every 4 hours, the battery life increases up to 10 years.

Waste water, fresh water, sewer & sewage treatment plants

Data logger for harsh environments

Use robust data loggers to monitor and manage challenging environments such as sewers and shafts. Transfer the collected data wirelessly to a central platform. Analyse your data to ensure you never miss an event in the sewer again and protect the environment.

Local or mobile radio

This is how your data is transferred

Wählen Sie zwischen Local, Connected oder Complete – je nachdem wie Ihre Daten übertragen werden sollen. Discover the advantages and disadvantages of the various types of gas detectors here.

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

H2S, NH3 oder H2O2

Choose your suitable sensor

Various sensors are available for the myDatasens gas detectors, depending on the application: H2S, NH3 or H2O2.

What factors determine the choice of the right sensor? What is the difference between nominal and maximum measuring range? At what intervals do the sensors need to be calibrated? Get an insight in the video.

myDatasensH2S

Efficient measurement of H2S

The myDatasens is available with a variety of H2S sensors. When it comes to measuring and reducing H2S levels in the ambient air, the myDatasensH2S is the perfect choice for a gas detector. Thanks to its innovative sensor replacement concept, it provides reliable measurements for years without any gaps in the data.

Reduce your efforts to an absolute minimum. You can conveniently read the data online. Receive alerts, control pumps fully automatically and generate reports. The myDatasensH2S and the included platform support you with many more tasks.

Sensor as a Service

How to increase the measurement quality

To improve the quality of your campaign’s measurements, it is necessary to calibrate your sensors professionally every six months. The ‘Sensor as a Service’ offer includes the necessary gas sensors, as well as their preparation and replacement.

Sounds interesting? Please contact our sales department for more information about this offer.

Stop unnecessary effort & unnecessary costs

Innovative sensor exchange

Please note that the sensor module must be replaced after a certain period of time. Thanks to our innovative sensor replacement system, this is quick and easy for you. Furthermore, there will be no more data gaps and resources will be saved.

Read more about the process and the advantages here.

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

GasBuster App

Need help with commissioning?

With the GasBuster app, you can conveniently read the current values on site. Both gas concentration and temperature are displayed in the app. You can swipe to switch between all sensors within range.

The GasBuster communicates with your smartphone. You can then synchronise this data with the server via your smartphone’s GSM connection. This means that, depending on how often the measuring point is visited, your measurements are available worldwide on the server. GasBuster is available for Android and iOS.

Apple App Store Icon Google Play Store

Product configurator

You can use the runtime calculator to estimate both the autonomous runtime of the application and the associated costs. Actual costs and energy consumption depend on measurement conditions such as reception quality and ambient temperature. You can find detailed information on the tariffs here.

Technical data

myDatasens
Item no. 300654 Local/Connected
300655 ATEX Local/Connected
300656 Complete
300657 ATEX Complete
Inputs 1 x Gas sensor module
Input configuration
  • H2S 7H
  • H2S BE
  • H2S B1
  • H2S BH
  • H2S C50
  • NH3
  • H2O2
Measuring range / Resolution
  • H2S 7H (0-200ppm; max. 1,000ppm; resolution: 0.25ppm)
  • H2S BE (0-2,000ppm; max. 3,900ppm; resolution: 0.5ppm)
  • H2S B1 (0-200ppm; max. 500ppm; resolution: 0.05ppm)
  • H2S BH (0-50ppm, max. 200ppm; resolution: 0.02ppm)
  • H2S C50 (0-50ppm; max. 100ppm; resolution: 0.03ppm)
  • NH3 (0-50ppm; max. 100ppm; resolution: 0.5ppm)
  • H2O2 (0-100ppm, max. 200ppm; resolution: 0.2ppm)
Sensor supply Battery in the gas sensor module
Temperature sensor Sensor in gas module -20...+50°C
Internal sensors and measured values
  • SOC (state of charge)
  • Battery life in days
  • Mobile strength
  • Humidity and temperature in the device
Outputs 1x mA Out (Option)
Power supply Internal battery 2x Li-SOCl2 (D-cell)
Battery life time
  • Battery life 10 years with 1-minute measurement interval and 4-hour data transmission
  • Battery life 6 years with 1-minute measurement interval and 15-minute data transmission
Protection class Device: IP66 / IP68 / IP69 (IP68: 105 days@1m)
Sensor: IP66
Ex certification ATEX Zone 1 ( II 2 G Ex ib IIB T3 Gb)
Display 1.5" Full Color Display
Dimensions 106 x 169 x 61mm (with protective armour)
Data transmission
  • LTE-M Europe
Product Document Category Revision Hardware Version
myDatasensH2S1000 LTE-M Fact Sheet 07 from Hw 4.0
myDatasensH2S1000 Radio Fact Sheet 07 from Hw 3.0
myDatasensH2S1000 2G/3G Fact Sheet 07 from Hw 3.0
myDatasensH2S1000 2G/3G Zone 1 Fact Sheet 07 from Hw 3.0
myDatasensH2S1000 Radio Zone 1 Fact Sheet 07 from Hw 3.0
myDatasensH2S1000 LTE-M ATEX Zone 1 Fact Sheet 07 from Hw 5.0
myDatasensH2S1000 LTE-M Manual 11 from Hw 4.0
myDatasensH2S1000 Radio Manual 11 from HW 3.0
myDatasensH2S1000 2G/3G Manual 03 from Hw 1.2
myDatasensH2S1000 Radio Zone 1 Manual 11 from Hw 3.0
myDatasensH2S1000 2G/3G Zone 1 Manual 05 from Hw 3.0
myDatasensH2S1000 LTE-M ATEX Zone 2 Manual 07 fom Hw 4.1
myDatasensH2S1000 LTE-M ATEX Zone 1 Manual 11 from Hw 5.0
BLE Gateway Zone 1
BLE 3G Gateway Zone 1
myDatalogGauge 2G/3G Zone 1
myDatasensH2S1000 2G/3G Zone 1
myDatasensH2S1000 Funk Zone 1
EU type examination certificate
1st supplement (ATEX Zone 1)
27.10.2021 from Hw 3.0
BLE Gateway Zone 1
BLE 3G Gateway Zone 1
myDatalogGauge 2G/3G Zone 1
myDatasensH2S1000 Radio Zone 1
myDatasensH2S1000 2G/3G Zone 1
EU type examination certificate (ATEX Zone 1) 06.09.2017 from Hw 2.0
H2O2 CB100 Sensormodul Zone 1
H2S 7H Sensormodul Zone 1
H2S C50 Sensormodul Zone 1
H2S BH Sensormodul Zone 1
H2S B1 Sensormodul Zone 1
H2S BE Sensormodul Zone 1
NH3 CR50 Sensormodul Zone 1
EU type examination certificate (ATEX Zone 1) 03.03.2017 from Hw 1.2
BLE Gateway Zone 1
BLE LTE-M Gateway Zone 1
myDatalogGauge LTE-M Zone 1
myDatasensH2S1000 LTE-M Zone 1
myDatasensH2S1000 Radio Zone 1
EU type examination certificate
2nd supplement (ATEX Zone 1)
21.07.2023 from Hw 5.0
BLE & LTE-M Gateway
myDatasensH2S1000 LTE-M
EU Declaration of Conformity 15.07.2025 from Hw 4.0
BLE Gateway Zone 1
myDatasensH2S1000 Radio Zone 1
EU Declaration of Conformity 11.11.2021 from Hw 3.0
BLE LTE-M Gateway Zone 1
myDatalogGauge LTE-M Zone 1
myDatasensH2S1000 LTE-M Zone 1
EU Declaration of Conformity 15.07.2025 from Hw 5.0
H2S 7H Sensor modul Zone 1
H2S C50 Sensor modul Zone 1
H2S BH Sensor modul Zone 1
H2S B1 Sensor modul Zone 1
H2S BE Sensor modul Zone 1
H2O2 CB100 Sensor modul Zone 1
EU Declaration of Conformity 18.01.2021 current
myDatasensH2S1000 LTE-M
myDatasensH2S1000 LTE-M Zone 1
myDatasensH2S1000 2G/3G
myDatasensH2S1000 2G/3G Zone 1
myDatasensH2S1000 Radio
myDatasensH2S1000 Radio Zone 1
3D View Hw 1.0 from Hw 1.0
H2S 7H
H2S BE
H2S B1 H2S BH H2S C50 H2O2 CB100 NH3 CR50
Manufacturer City Technology Alphasense Alphasense Alphasense Membrapor Membrapor Membrapor
Measurment Range 0-200ppm;
max. 1,000ppm
0-2,000ppm;
max. 3,900ppm
0-200ppm;
max. 500ppm
0-50ppm;
max. 200ppm
0-50ppm;
max. 100ppm
0-100ppm;
max. 200ppm
0-50ppm;
max. 100ppm
Resolution 0.25ppm 0.5ppm 0.05ppm 0.02ppm 0.03ppm 0.2ppm 0.5ppm
Repeatability 1% 2% 2% 3%
Calibration point Synthetic air – 150ppm H2S Synthetic air – 150ppm H2S Nitrogen – 30ppm H2S Nitrogen – 5ppm H2S Nitrogen – 30ppm H2S Gas generator Nitrogen – 20ppm NH3
Lifetime 24 months in air 24 months in air 24 months in air 24 months in air 24 months in air 24 months in air 24 months in air
Zero point
shift
2ppm 4ppm 1.5ppm 1.5ppm 0.1ppm N.D. -5ppm