The myDatasensH2S continuously measures the H2S concentration in the air. The lower the H2S concentration, the more durable the infrastructure. The data logger is designed for use in harsh environments such as sewers and wastewater treatment plants and is certified for operation in ATEX Zone 1. The measurement data is stored on the web platform. Ultra Low Power technology results in a lifetime battery life.
Actively combat the stench of unhealthy hydrogen sulphide and the corrosion of components. By permanently recording H2S levels, you make better data-driven decisions. Optimise the use of chemicals and expand the application with automated dosing control. In targeted measurement campaigns over a representative period of time, you determine the load for the dimensioning of future systems or for improvements to the existing sewer system.
Old H2S sensor out, new H2S sensor in - thanks to the magnetic contact, correct insertion is guaranteed. Immediate sensor replacement on site means that there are no more data gaps. While the new H2S sensor is busy measuring, the old H2S sensor is recalibrated and then reused. This saves you costs, time and resources and gives you the advantage of seamless data collection.
The myDatasensH2S is certified for use in the hazardous area of ATEX Zone 1. The data is transmitted via mobile radio directly from the ATEX zone to the central web platform.
The 1.5" full colour OLED display shows the current measured values as well as status information, such as the time until the next calibration or the time until the next device service, directly on site without additional software.
With the rubber armour, the BLE Gateway meter is well protected for the harsh environment it was designed for. All parts on the device are made of plastic to prevent corrosion by the extremely aggressive gases. The repairability and low-cost spare parts ensure cost-efficient operation.
Bluetooth Smart or 2G/3G
In order to be able to select the appropriate variant for the respective application, the necessary knowledge about the respective topic is required. In order to decide in which form the data transmission of the myDatasensH2S should take place, you will find an overview here.
What we offer
Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren
H2S and NH3
What is the difference between nominal and maximum value? What is the resolution and zero offset? What range will your readings be in and what accuracy do you need?
In addition to a variety of H2S sensors, the myDatasens is available with NH3 and H2O2 sensors .
The Microtronics team will be happy to advise you on the selection of the right sensor for your application.
Sensor as a Service
To increase the measurement quality of your campaigns, a semi-annual professional calibration of the sensors is essential. “Sensor as a Service” provides you with the required gas sensors and includes sensor preparation and replacement.
Practical & fast
GasBuster
With the GasBuster app, you can conveniently read out the current values on site. H2S concentration and temperature are displayed in the app. Swipe to switch between all sensors within your reach. The GasBuster communicates with your smartphone via BLE. You can synchronise the data to the server via the GSM connection of your smartphone. Depending on the frequency of visits to the measuring point, your measured values are thus available on the server worldwide. GasBuster is available for Android and iOS.
Lokale oder dezentrale Steuerung
Several options are available for demand-based dosing control to reduce measured H2S levels.
With the help of the runtime calculator, you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.
Producttitle | myDatasensH2S1000 |
---|---|
Item no. | myDatasensH2S1000 |
Ex certification | Optional:
|
Power supply | Battery |
Battery Life Time | Gateway:
Sensor: 24 months |
Data memory | Internal flash memory for up to 82.776 measurement cycles |
Dimensions | 106 x 169 x 61mm (with protective armour) |
Protection class | Complete system: IP66 Gateway: IP66 / IP68 / IP69 (IP68: max. immersion depth 1m for max. 5h ) Sensor: IP66 |
Operating temperature | -20...+50°C |
Display | 1,5" Full Color Display, Resolution 128 x 128 |
Number of sensors | 1 x H2S 7H Sensormodul |
Sensor module | H2S Gas Nominal: 0-200ppm, Peak Load: 1000ppm Resolution: 0,25ppm, Accuracy: 1%, T 90 Time: <=35s, Abrasion: 0 ... 100% |
Measurement range gateway | Internal Temperature: -20...+60°C Internal Air Humidity: 0...100% rH Battery SOC (State of Charge): 0 ... 100% BLE Signal Quality: -50dBm ... -110dBm GSM Signal Quality: -50dBm ... -110dBm |
Measurement method | electrochemical gas sensor |
Temperature sensor | Measurement range: -20...+50°C Resolution: 0,1°C |
Data transmission |
|
SIM | integrated SIM chip |
Positioning | for the 3G variant by using GSM cell location |
Name | Hardware Version | Document Category | Revision |
---|
H2S 7H |
H2S BE |
H2S B1 | H2S BH | H2S C50 | H2O2 CB100 | NH3 CR50 | |
---|---|---|---|---|---|---|---|
Manufacturer | City Technology | Alphasense | Alphasense | Alphasense | Membrapor | Membrapor | Membrapor |
Measurment Range | 0-200ppm; max. 1.000ppm |
0-2.000ppm; max. 3.900ppm |
0-200ppm; max. 500ppm |
0-50ppm; max. 200ppm |
0-50ppm; max. 100ppm |
0-100ppm; max. 200ppm |
0-50ppm; max. 100ppm |
Resolution | 0,25ppm | 0,5ppm | 0,05ppm | 0,02ppm | 0,03ppm | 0,2ppm | 0,5ppm |
Repeatability | 1% | — | — | — | 2% | 2% | 3% |
Calibration point | Synthetic air – 150ppm H2S | Synthetic air – 150ppm H2S | Nitrogen – 30ppm H2S | Nitrogen – 5ppm H2S | Nitrogen – 30ppm H2S | Gas generator | Nitrogen – 20ppm NH3 |
Lifetime | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air |
Zero offset |
2ppm | 4ppm | 1,5ppm | 1,5ppm | 0,1ppm | N.D. | -5ppm |
Producttitle | myDatasensH2S1000 |
---|---|
Item no. | myDatasensH2S1000 |
Ex certification | Optional:
|
Power supply | Battery |
Battery Life Time | Gateway:
Sensor: 24 months |
Data memory | Internal flash memory for up to 82.776 measurement cycles |
Dimensions | 106 x 169 x 61mm (with protective armour) |
Protection class | Complete system: IP66 Gateway: IP66 / IP68 / IP69 (IP68: max. immersion depth 1m for max. 5h ) Sensor: IP66 |
Operating temperature | -20...+50°C |
Display | 1,5" Full Color Display, Resolution 128 x 128 |
Number of sensors | 1 x H2S 7H Sensormodul |
Sensor module | H2S Gas Nominal: 0-200ppm, Peak Load: 1000ppm Resolution: 0,25ppm, Accuracy: 1%, T 90 Time: <=35s, Abrasion: 0 ... 100% |
Measurement range gateway | Internal Temperature: -20...+60°C Internal Air Humidity: 0...100% rH Battery SOC (State of Charge): 0 ... 100% BLE Signal Quality: -50dBm ... -110dBm GSM Signal Quality: -50dBm ... -110dBm |
Measurement method | electrochemical gas sensor |
Temperature sensor | Measurement range: -20...+50°C Resolution: 0,1°C |
Data transmission |
|
SIM | integrated SIM chip |
Positioning | for the 3G variant by using GSM cell location |
base price | - |