The myDatasensH2S continuously measures the H2S concentration in the air. The data logger is designed for the operation in harsh environments such as sewers and wastewater treatment plants and is certified for operation in ATEX Zone 1. The measurement data is stored on the web platform. The battery life is up to 36 months due to the Ultra Low Power technology.
Actively combat the smell of harmful hydrogen sulphide and the corrosion of components. Make better data-driven decisions by permanently recording H2S levels. Optimise the use of chemicals and expand the application with automated dosing control. In targeted measurement campaigns over a representative period, you can determine the load for the dimensioning of future systems or for improvements to the existing duct system.
Old H2S sensor out, new H2S sensor in - thanks to the magnetic contact, correct insertion is guaranteed. While the new H2S sensor is busy measuring, the old H2S sensor is recalibrated and then used again. In this way, you save costs, time and resources and enjoy the advantage of seamless data acquisition.
The myDatasensH2S is certified for use in the potentially explosive area of ATEX Zone 1. The data is transmitted via mobile radio directly from the ATEX zone to the central web platform.
The 1.5" full colour OLED display shows the current measured values as well as status information such as the time until the next calibration and service directly on site without additional software.
With the rubber armour, the device is well protected for the harsh environment for which it was designed. All parts on the unit are made of plastic to prevent corrosion from the extremely aggressive gases. Repairability and inexpensive spare parts ensure cost-efficient operation.
What we offer
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationH2Sand NH3
What is the difference between nominal and maximum value? What is the resolution and zero offset? What range will your readings be and what accuracy do you need?
The Microtronics team will be happy to advise you on the selection of the right sensor for your application.
Sensor as a Service
To increase the measurement quality of your campaigns, professional calibration of the sensors every six months is essential. “Sensor as a Service” provides you with the required gas sensors and includes sensor preparation and replacement.
With the brand new GasBuster App you can comfortably read out the current values at the site. H2S concentration and temperature are displayed in the app. Swipe to switch between all sensors within your reach. The GasBuster communicates with your smarphone via BLE. You can synchronize the data to the server via the GSM of your smartphone. Depending on the frequency of the measurement site visits the values are available on the server worldwide. GasBuster is available for Android and iOS.
| Producttitle | myDatasensH2S1000 |
|---|---|
| Item no. | myDatasensH2S1000 |
| Ex certification | Optional:
|
| Power supply | Battery |
| Battery Life Time | Gateway:
Sensor: 24 months |
| Data memory | Internal flash memory for up to 82.776 measurement cycles |
| Dimensions | 106 x 169 x 61mm (with protective armour) |
| Protection class | Complete system: IP66 Gateway: IP66 / IP68 / IP69 (IP68: max. immersion depth 1m for max. 5h ) Sensor: IP66 |
| Operating temperature | -20...+50°C |
| Display | 1,5" Full Color Display, Resolution 128 x 128 |
| Number of sensors | 1 x H2S 7H Sensormodul |
| Sensor module | H2S Gas Nominal: 0-200ppm, Peak Load: 1000ppm Resolution: 0,25ppm, Accuracy: 1%, T 90 Time: <=35s, Abrasion: 0 ... 100% |
| Measurement range gateway | Internal Temperature: -20...+60°C Internal Air Humidity: 0...100% rH Battery SOC (State of Charge): 0 ... 100% BLE Signal Quality: -50dBm ... -110dBm GSM Signal Quality: -50dBm ... -110dBm |
| Measurement method | electrochemical gas sensor |
| Temperature sensor | Measurement range: -20...+50°C Resolution: 0,1°C |
| Data transmission |
|
| SIM | integrated SIM chip |
| Positioning | for the 3G variant by using GSM cell location |
| base price | - |
| Configure product |
| Product | Document Category | Revision | Hardware Version | |
|---|---|---|---|---|
| myDatasensH2S1000 Funk | Handbuch | 11 | ab HW 3.0 |
|
| myDatasensH2S1000 Funk Zone 1 | Handbuch | 11 | ab Hw 3.0 |
|
| myDatasensH2S1000 2G/3G | Handbuch | 05 | ab Hw 3.0 |
|
| myDatasensH2S1000 2G/3G Zone 1 | Handbuch | 05 | ab Hw 3.0 |
|
| BLE mA Link | Handbuch | 01 | ab Hw 1.1 |
|
| myDatasensH2S1000 2G/3G Zone 1 | Fact Sheet | 07 | ab Hw 3.0 |
|
| myDatasensH2S1000 Funk | Fact Sheet | 07 | ab Hw 3.0 |
|
| myDatasensH2S1000 2G/3G | Fact Sheet | 07 | ab Hw 3.0 |
|
| myDatasensH2S1000 Funk Zone 1 | Fact Sheet | 07 | ab Hw 3.0 |
|
| BLE Gateway BLE Gateway Zone 1 myDatasensH2S1000 Funk myDatasensH2S1000 Funk Zone 1 |
Release Info - Controller | 01v033 | aktuell |
|
| BLE & 3G Gateway BLE & 3G Gateway Zone 1 myDatalogEx myDatalogGauge 2G/3G Zone 1 myDatasensH2S1000 2G/3G myDatasensH2S1000 2G/3G Zone 1 |
Release Info - Controller | 02v017 | aktuell |
|
| BLE Gateway myDatasensH2S1000 Funk |
Release Info - Hardware | 05v001 | aktuell |
|
| BLE Gateway Zone 1 myDatasensH2S1000 Funk Zone 1 |
Release Info - Hardware | 05v001 | aktuell |
|
| BLE & 3G Gateway BLE & LTE-M Gateway myDatasensH2S1000 2G/3G myDatasensH2S1000 LTE-M |
Release Info - Hardware | 05v002 | aktuell |
|
| BLE & 3G Gateway Zone 1 BLE & LTE-M Gateway Zone 1 myDatalogGauge 2G/3G Zone 1 myDatalogGauge LTE-M Zone 1 myDatasensH2S1000 2G/3G Zone 1 myDatasensH2S1000 LTE-M Zone 1 |
Release Info - Hardware | 05v002 | aktuell |
|
| H2O2 CB100 Sensormodul Zone 1 H2S 7H Sensormodul Zone 1 H2S C50 Sensormodul Zone 1 H2S BH Sensormodul Zone 1 H2S B1 Sensormodul Zone 1 H2S BE Sensormodul Zone 1 NH3 CR50 Sensormodul Zone 1 |
Release Info - Hardware | 04v001 | aktuell |
|
| BLE Gateway Zone 1 BLE & 3G Gateway Zone 1 myDatalogGauge 2G/3G Zone 1 myDatasensH2S1000 Funk Zone 1 myDatasensH2S1000 2G/3G Zone 1 |
EU-Baumusterprüfbescheinigung (ATEX Zone 1) | 06.09.2017 | ab Hw 2.0 |
|
| BLE & 3G Gateway myDatasensH2S1000 2G/3G |
EU-Konformitätserklärung | 15.07.2025 | ab Hw 3.0 |
|
| BLE & 3G Gateway Zone 1 myDatalogGauge 2G/3G Zone 1 myDatasensH2S1000 2G/3G Zone 1 |
EU-Konformitätserklärung | 15.07.2025 | ab Hw 3.0 |
|
| BLE Gateway myDatasensH2S1000 Funk |
EU-Konformitätserklärung | 11.11.2021 | ab Hw 3.0 |
|
| BLE Gateway Zone 1 myDatasensH2S1000 Funk Zone 1 |
EU-Konformitätserklärung | 11.11.2021 | ab Hw 3.0 |
|
| H2S 7H Sensormodul Zone 1 H2S C50 Sensormodul Zone 1 H2S BH Sensormodul Zone 1 H2S B1 Sensormodul Zone 1 H2S BE Sensormodul Zone 1 H2O2 CB100 Sensormodul Zone 1 |
EU-Konformitätserklärung | 18.01.2021 | aktuell |
|
| myDatasensH2S1000 Funk myDatasensH2S1000 Funk Zone 1 |
Release Info - App. Model | 02v000 | aktuell |
|
| myDatasensH2S1000 2G/3G myDatasensH2S1000 2G/3G Zone 1 |
Release Info - App. Model | 02v000 | aktuell |
|
| H2S 7H | H2S BE | H2S B1 | H2S BH | H2S C50 | H2O2 CB100 | NH3 CR50 | |
|---|---|---|---|---|---|---|---|
| Manufacturer | City Technology | Alphasense | Alphasense | Alphasense | Membrapor | Membrapor | Membrapor |
| Measurment Range | 0-200ppm; max. 1.000ppm |
0-2.000ppm; max. 3.900ppm |
0-200ppm; max. 500ppm |
0-50ppm; max. 200ppm |
0-50ppm; max. 100ppm |
0-100ppm; max. 200ppm |
0-50ppm; max. 100ppm |
| Resolution | 0,25ppm | 0,5ppm | 0,05ppm | 0,02ppm | 0,03ppm | 0,2ppm | 0,5ppm |
| Repeat Accuracy | 1% | — | — | — | 2% | 2% | 3% |
| Calibration point | Synthetic air – 150ppm H2S | Synthetic air – 150ppm H2S | Nitrogen – 30ppm H2S | Nitrogen – 5ppm H2S | Nitrogen – 30ppm H2S | Gas generator | Nitrogen – 20ppm NH3 |
| Expected Operating Time | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air | 24 months in the air |
| Zero Shift | 2ppm | 4ppm | 1,5ppm | 1,5ppm | 0,1ppm | N.D. | -5ppm |
You are currently viewing a placeholder content from HubSpot. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationIn order to use our live chat, you must agree to the loading of Hubspot cookies. You can find out more about this in our privacy policy.
You are currently viewing a placeholder content from Vimeo. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Facebook. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Hubspot Embedded Content. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from HubSpot. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Hubspot Meetings. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from Instagram. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from reCAPTCHA. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from X. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More Information