{"id":34899,"date":"2022-10-20T13:12:24","date_gmt":"2022-10-20T11:12:24","guid":{"rendered":"https:\/\/microtronics.com\/?p=34899"},"modified":"2024-04-22T16:58:18","modified_gmt":"2024-04-22T14:58:18","slug":"stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control","status":"publish","type":"post","link":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/","title":{"rendered":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">H<sub>2<\/sub>S occurs in industrial and urban wastewater networks. A reaction can occur due to the biological process on the transport path of the wastewater into the wastewater treatment plant. The characteristic smell of rotten eggs develops.<\/p>\n\n<h2 class=\"wp-block-heading\">Typical problem areas in the sewage network<\/h2>\n\n<ul class=\"wp-block-list\">\n<li>Above the water level in the sewage pipe<\/li>\n\n\n\n<li>After waste water pressure lines<\/li>\n\n\n\n<li>Changing steam or waste water turbulence<\/li>\n\n\n\n<li>Lifting pipe, sewer jumper, siphon<\/li>\n\n\n\n<li>Through start-stop pump cycles<\/li>\n\n\n\n<li>In case of sewer overload<\/li>\n\n\n\n<li>In the sand trap<\/li>\n\n\n\n<li>If the slope is too steep<\/li>\n\n\n\n<li>At the sewage treatment plant<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\" id=\"h-so-funktioniert-s-in-der-praxis\">How it works in practice<\/h2>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/07\/h2s-in-sewer-tunnel-cross-section-1024x606.png\" alt=\"h2s_cross section\" class=\"wp-image-28562\"\/><\/figure>\n\n<ol class=\"wp-block-list\" style=\"list-style-type:1\">\n<li>Monitoring of H<sub>2<\/sub>S concentration in the sewer with <a href=\"https:\/\/microtronics.com\/en\/produkt\/mydatasensh2s1000\/\" target=\"_blank\" rel=\"noreferrer noopener\">ATEX certified equipment<\/a>.<\/li>\n\n\n\n<li>Configuration of the unit in the sewer remotely via the <a href=\"https:\/\/microtronics.com\/en\/iot-platform\/\" target=\"_blank\" rel=\"noreferrer noopener\">IoT platform<\/a>. The data recorded in the sewer are transmitted to the platform at regular intervals via mobile radio and are available there for reports. Alarming and triggering of actions when a defined value is exceeded.<\/li>\n\n\n\n<li>Automatic dosing control with the <a href=\"https:\/\/microtronics.com\/en\/produkt\/mydatalog-c3\/#device-type\" target=\"_blank\" rel=\"noreferrer noopener\">rapidM2M C3<\/a> for preventive dosing of appropriate chemicals to <a href=\"https:\/\/microtronics.com\/en\/blog-en\/5-ways-to-monitor-and-control-h2s\/\" target=\"_blank\" rel=\"noreferrer noopener\">reduce H2S in the sewer<\/a>.<\/li>\n<\/ol>\n\n<h2 class=\"wp-block-heading\">Advantages of a modern H<sub>2<\/sub>S monitoring solution<\/h2>\n\n<p class=\"wp-block-paragraph\">A modern monitoring solution helps to quickly and efficiently identify problem areas and creates transparency about the condition. This shows how critical the situation actually is. Action steps can be derived and public danger zones can be cordoned off. Immediate dosing of reagents in the pump sump area to reduce the H<sub>2<\/sub>S concentration and monitoring the effectiveness of the measures with reporting as evidence provide a remedy.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Detection of critical situations via permanent monitoring of the gas concentration<\/li>\n\n\n\n<li>Automated data preparation and e-mail reporting<\/li>\n\n\n\n<li>Alerting in case of unexpected increase in concentration<\/li>\n\n\n\n<li>Innovative sensor exchange concept for maximum efficiency in the calibration process<\/li>\n\n\n\n<li>Reduction of gas concentration via remote dosing control to minimise corrosion<\/li>\n\n\n\n<li>Optimised treatment of the reactant to save costs and the environment<\/li>\n\n\n\n<li>Automated operating materials logistics via consumption monitoring with fill level alarming<\/li>\n\n\n\n<li>Reduction of trips to a minimum thanks to maintenance concept adapted to calibration cycles<\/li>\n\n\n\n<li>Efficient staff deployment through simplified management via remote login<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\" id=\"h-mit-dosiersteuerung-fur-alles-gerustet\">Equipped for everything with dosing control<\/h2>\n\n<p class=\"wp-block-paragraph\">The H<sub>2<\/sub>S monitoring solution can additionally be combined with a dosing control. Thus, either event-based, i.e. as soon as odour formation occurs, or preventive chemicals can be released to reduce the H<sub>2<\/sub>S concentration. In addition, continuous operation and automated logistics with low personnel costs can be ensured by measuring the level of the reaction medium.<\/p>\n\n<h2 class=\"wp-block-heading\">Special features of Microtronics technology<\/h2>\n\n<p class=\"wp-block-paragraph\">The myDatasens devices have been perfectly adapted to the challenging application needs. This results in a highly optimised TCO (Total Cost of Ownership) for the operator. This makes it the most efficient H<sub>2<\/sub>S monitoring solution available on the market today.<\/p>\n\n<h3 class=\"wp-block-heading\">Comparison of Microtronic&#8217;s solution with that of its market competitors:<\/h3>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><\/td><td><strong>Microtronics<\/strong><\/td><td><strong>Market companion<\/strong><\/td><\/tr><tr><td>Assembly time<\/td><td>&lt;5 minutes, no entry necessary<\/td><td>10-30 minutes, partial screwing<\/td><\/tr><tr><td>Sensor replacement time<\/td><td>&lt;1 minute, no entry necessary<\/td><td>10-20 minutes or unit exchange<\/td><\/tr><tr><td>Travel frequency<\/td><td>Max. 2x per year, calibration<\/td><td>Several times per year, calibration, battery replacement<\/td><\/tr><tr><td>Battery life time<\/td><td>10 years<\/td><td>8 months<\/td><\/tr><tr><td>ATEX<\/td><td>Certified for zone 1<\/td><td>Not certified<\/td><\/tr><tr><td>Measurement data storage capacity with 1 minute data grid<\/td><td>180 days<\/td><td>29 days<\/td><\/tr><tr><td>Measurement data storage capacity with 5 minute data grid<\/td><td>24 months<\/td><td>6 months<\/td><\/tr><tr><td>Data points<\/td><td>261.800<\/td><td>42.000<\/td><\/tr><tr><td>Data readout<\/td><td>&#8211; Remotely available on the server via mobile radio<br\/>&#8211; Local with app<br\/>&#8211; Locally via wireless USB stick<\/td><td>Cable<\/td><\/tr><tr><td>Cloud storage<\/td><td>Yes<\/td><td>Optional<\/td><\/tr><tr><td>Full Color Display<\/td><td>Yes<\/td><td>No<\/td><\/tr><tr><td>Maintenance interval and service interval display<\/td><td>Yes<\/td><td>No<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">The H<sub>2<\/sub>S measuring devices are adapted to the needs of the customers. Thanks to the maintenance concept, resources and costs are saved. Continuous data collection helps to detect damage at an early stage, avoid failures and optimise processes.<\/p>\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n<p class=\"wp-block-paragraph\">With the H<sub>2<\/sub>S monitoring including dosing control from Microtronics, you have the hydrogen sulphide concentration in the ambient air at a glance. Now it is possible for you to initiate effective measures in a targeted manner.<\/p>\n\n<p class=\"wp-block-paragraph\">Microtronics partner <a href=\"https:\/\/microtronics.com\/en\/?p=23268\">HeGo Biotec<\/a> demonstrates how the odour nuisance was stopped using the example of Berlin-K\u00f6penick. Thanks to continuous H<sub>2<\/sub>S measurement, the corresponding chemicals can now be dosed as needed.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hydrogen sulphide can occur around the sewage and sewer system. If the concentration is too high, H<sub>2<\/sub>S is even dangerous. You can read <a href=\"https:\/\/microtronics.com\/en\/blog-en\/protect-people-and-infrastructure-from-damage-caused-by-hydrogen-sulphide\/\" target=\"_blank\" rel=\"noreferrer noopener\">here<\/a> which areas are negatively affected by the colourless gas.<\/p>\n<p>If one knows about the dangers, countermeasures can be taken in time. H<sub>2<\/sub>S monitoring with integrated dosing control is the ideal solution here.<\/p>\n","protected":false},"author":8,"featured_media":34952,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[765,764],"tags":[888,1812,862,1002,1136],"class_list":["post-34899","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-blog-en","tag-atex-en","tag-gasmonitoring-en","tag-h2s-en-2","tag-h2s-combat","tag-hydrogen-sulphide"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.3 (Yoast SEO v28.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control - Microtronics<\/title>\n<meta name=\"description\" content=\"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control\" \/>\n<meta property=\"og:description\" content=\"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/\" \/>\n<meta property=\"og:site_name\" content=\"Microtronics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Microtronics.Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2022-10-20T11:12:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-22T14:58:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1125\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Bettina\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Microtronics\" \/>\n<meta name=\"twitter:site\" content=\"@Microtronics\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Bettina\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/\"},\"author\":{\"name\":\"Bettina\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#\\\/schema\\\/person\\\/c56b76fa5fb59df0ead685ef7798f9c8\"},\"headline\":\"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control\",\"datePublished\":\"2022-10-20T11:12:24+00:00\",\"dateModified\":\"2024-04-22T14:58:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/\"},\"wordCount\":695,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Doris_Schaltschrank.jpg\",\"keywords\":[\"ATEX\",\"Gasmonitoring\",\"H2S\",\"H2S Combat\",\"Hydrogen sulphide\"],\"articleSection\":[\"Applications\",\"Blog\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/\",\"url\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/\",\"name\":\"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control - Microtronics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Doris_Schaltschrank.jpg\",\"datePublished\":\"2022-10-20T11:12:24+00:00\",\"dateModified\":\"2024-04-22T14:58:18+00:00\",\"description\":\"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#primaryimage\",\"url\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Doris_Schaltschrank.jpg\",\"contentUrl\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Doris_Schaltschrank.jpg\",\"width\":2000,\"height\":1125,\"caption\":\"C3 im Schaltschrank\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/blog-en\\\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/microtronics.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/microtronics.com\\\/en\\\/category\\\/blog-en\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/microtronics.com\\\/en\\\/\",\"name\":\"Microtronics\",\"description\":\"Earn money with IoT - IoT as a Service\",\"publisher\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/microtronics.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#organization\",\"name\":\"Microtronics Engineering GmbH\",\"url\":\"https:\\\/\\\/microtronics.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/mt-logo.svg\",\"contentUrl\":\"https:\\\/\\\/microtronics.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/mt-logo.svg\",\"width\":252,\"height\":60,\"caption\":\"Microtronics Engineering GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Microtronics.Engineering\",\"https:\\\/\\\/x.com\\\/Microtronics\",\"https:\\\/\\\/www.instagram.com\\\/microtronics.engineering\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/microtronics\",\"http:\\\/\\\/www.youtube.com\\\/user\\\/MicrotronicsM2M\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/microtronics.com\\\/en\\\/#\\\/schema\\\/person\\\/c56b76fa5fb59df0ead685ef7798f9c8\",\"name\":\"Bettina\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g\",\"caption\":\"Bettina\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control - Microtronics","description":"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/","og_locale":"en_US","og_type":"article","og_title":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control","og_description":"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.","og_url":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/","og_site_name":"Microtronics","article_publisher":"https:\/\/www.facebook.com\/Microtronics.Engineering","article_published_time":"2022-10-20T11:12:24+00:00","article_modified_time":"2024-04-22T14:58:18+00:00","og_image":[{"width":2000,"height":1125,"url":"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg","type":"image\/jpeg"}],"author":"Bettina","twitter_card":"summary_large_image","twitter_creator":"@Microtronics","twitter_site":"@Microtronics","twitter_misc":{"Written by":"Bettina","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#article","isPartOf":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/"},"author":{"name":"Bettina","@id":"https:\/\/microtronics.com\/en\/#\/schema\/person\/c56b76fa5fb59df0ead685ef7798f9c8"},"headline":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control","datePublished":"2022-10-20T11:12:24+00:00","dateModified":"2024-04-22T14:58:18+00:00","mainEntityOfPage":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/"},"wordCount":695,"commentCount":0,"publisher":{"@id":"https:\/\/microtronics.com\/en\/#organization"},"image":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#primaryimage"},"thumbnailUrl":"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg","keywords":["ATEX","Gasmonitoring","H2S","H2S Combat","Hydrogen sulphide"],"articleSection":["Applications","Blog"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/","url":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/","name":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control - Microtronics","isPartOf":{"@id":"https:\/\/microtronics.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#primaryimage"},"image":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#primaryimage"},"thumbnailUrl":"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg","datePublished":"2022-10-20T11:12:24+00:00","dateModified":"2024-04-22T14:58:18+00:00","description":"Keep an eye on the hydrogen sulphide concentration in the ambient air thanks to modern H2S monitoring solution incl. dosing control.","breadcrumb":{"@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#primaryimage","url":"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg","contentUrl":"https:\/\/microtronics.com\/wp-content\/uploads\/2022\/10\/Doris_Schaltschrank.jpg","width":2000,"height":1125,"caption":"C3 im Schaltschrank"},{"@type":"BreadcrumbList","@id":"https:\/\/microtronics.com\/en\/blog-en\/stop-the-hydrogen-sulphide-h2s-monitoring-including-dosing-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/microtronics.com\/en\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/microtronics.com\/en\/category\/blog-en\/"},{"@type":"ListItem","position":3,"name":"Stop the Hydrogen Sulphide: H2S Monitoring including Dosing Control"}]},{"@type":"WebSite","@id":"https:\/\/microtronics.com\/en\/#website","url":"https:\/\/microtronics.com\/en\/","name":"Microtronics","description":"Earn money with IoT - IoT as a Service","publisher":{"@id":"https:\/\/microtronics.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/microtronics.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/microtronics.com\/en\/#organization","name":"Microtronics Engineering GmbH","url":"https:\/\/microtronics.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/microtronics.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/microtronics.com\/wp-content\/uploads\/2021\/05\/mt-logo.svg","contentUrl":"https:\/\/microtronics.com\/wp-content\/uploads\/2021\/05\/mt-logo.svg","width":252,"height":60,"caption":"Microtronics Engineering GmbH"},"image":{"@id":"https:\/\/microtronics.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/Microtronics.Engineering","https:\/\/x.com\/Microtronics","https:\/\/www.instagram.com\/microtronics.engineering\/","https:\/\/www.linkedin.com\/company\/microtronics","http:\/\/www.youtube.com\/user\/MicrotronicsM2M"]},{"@type":"Person","@id":"https:\/\/microtronics.com\/en\/#\/schema\/person\/c56b76fa5fb59df0ead685ef7798f9c8","name":"Bettina","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e5561149e5621608d96e314673117fe14d0bb970bb5d8c4de5a9f964495893fc?s=96&d=mm&r=g","caption":"Bettina"}}]}},"_links":{"self":[{"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/posts\/34899","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/comments?post=34899"}],"version-history":[{"count":17,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/posts\/34899\/revisions"}],"predecessor-version":[{"id":56652,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/posts\/34899\/revisions\/56652"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/media\/34952"}],"wp:attachment":[{"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/media?parent=34899"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/categories?post=34899"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microtronics.com\/en\/wp-json\/wp\/v2\/tags?post=34899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}