Stationary instrument for signal acquisition from 3 universal inputs and for controlling actuators via the integrated relay outputs or the digital interfaces.
Features:
– Interface to accommodate an M2xx module
– RS232 to SUB D socket
– RS485 to 2pin removable clamp
– CAN (not insulated) to 2pin. removable clamp
– LAN 10/100MBit (only when using a M23x module)
– SMA connection for mobile phone antenna
– SMA connector for BT/BLE/wifi antenna
– 3x universal input
– 2x parallel connection of a relay and optoswitch
– Backup battery for power failure message
– USB B mini for debugging
– Button and LED on the front panel
– Top-hat rail housing 70mm width
Modul M23x Wifi/2G/4G:
SIM: onboard
MCU: ARM Cortex M4
Modem: 4G EU – LTE Cat 1 bands 3, 7, 20; EGPRS dual-band, 900/1800 MHz
Wifi: Single-band 2,4 GHz, IEEE 802.11 b/g/n
Scope of delivery:
– myDatalogC3xx Base
– ZA8 Connector
– M23x Modul
The module is already installed in the device when it is delivered.
With the help of the runtime calculator, you can estimate the autonomous runtime of the application as well as the costs incurred. The actual costs and energy consumption depend on the measurement conditions, such as the reception quality and ambient temperature. Detailed information on the tariffs can be found here.
Producttitle | myDatalogC33x WIFI/2G/4G EU |
---|---|
Item no. | 301167 |
Power supply | 9...32VDC |
Data memory | 512 MB flash (file system, 3 MB for measurement data) 8 MB RAM 128kB FRAM |
Programming | In Studio with C-like scripting language built on PAWN |
Dimensions | 70 x 92 x 63mm (without antenna) |
Protection class | IP20 / IP40 (connection area/operating area) |
Operating temperature | -20...+60°C |
Inputs | 3 x analogue or digital (individually configurable per channel)
|
Resolution |
|
Outputs | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) |
Serial interfaces | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) |
Data transmission | 2G/4G Europe:
WiFi:
Network interface:
|
SIM | integrated SIM chip |
Positioning | by using GSM cell location |
Producttitle | myDatalogC33x WIFI/2G/4G EU | myDatalogC32x 2G/M1/NB1 World | myDatalogC32x 3G World | myDatalogC32x 2G/4G EU | myDatalogC33x WIFI/3G World |
---|---|---|---|---|---|
Item no. | 301167 | 301163 | 301164 | 301165 | 301166 |
Power supply | 9...32VDC | 9...32VDC | 9...32VDC | 9...32VDC | 9...32VDC |
Data memory | 512 MB flash (file system, 3 MB for measurement data) 8 MB RAM 128kB FRAM | 3MB internal flash memory | 3MB internal flash memory | 3MB internal flash memory | 512 MB flash (file system, 3 MB for measurement data) 8 MB RAM 128kB FRAM |
Programming | In Studio with C-like scripting language built on PAWN | In Studio with C-like scripting language built on PAWN | In Studio with C-like scripting language built on PAWN | In Studio with C-like scripting language built on PAWN | In Studio with C-like scripting language built on PAWN |
Dimensions | 70 x 92 x 63mm (without antenna) | 70 x 92 x 63mm (without antenna) | 70 x 92 x 63mm (without antenna) | 70 x 92 x 63mm (without antenna) | 70 x 92 x 63mm (without antenna) |
Protection class | IP20 / IP40 (connection area/operating area) | IP20 / IP40 (connection area/operating area) | IP20 / IP40 (connection area/operating area) | IP20 / IP40 (connection area/operating area) | IP20 / IP40 (connection area/operating area) |
Operating temperature | -20...+60°C | -20...+60°C | -20...+60°C | -20...+60°C | -20...+60°C |
Inputs | 3 x analogue or digital (individually configurable per channel)
| 3 x analogue or digital (individually configurable per channel)
| 3 x analogue or digital (individually configurable per channel)
| 3 x analogue or digital (individually configurable per channel)
| 3 x analogue or digital (individually configurable per channel)
|
Resolution |
|
|
|
|
|
Outputs | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) | 2 x Relay (with parallel pulse relay for setpoint output to, for example, dosing pumps; each channel can be configured individually) |
Serial interfaces | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) | 1 x RS485 (2-Leiter) 1 x CAN / CAN FD 1 x RS232 (4-Leiter) |
Data transmission | 2G/4G Europe:
WiFi:
Network interface:
| 2G/M1/NB1 World:
| 3G World:
| 2G/4G Europe:
| 2G/3G World:
WiFi:
Network interface:
|
SIM | integrated SIM chip | integrated SIM chip | integrated SIM chip | integrated SIM chip | integrated SIM chip |
Positioning | by using GSM cell location | by using GSM cell location | by using GSM cell location | by using GSM cell location | by using GSM cell location |
base price | € 883,80 excluding VAT | € 598,80 excluding VAT | € 622,20 excluding VAT | € 676,50 excluding VAT | € 870,50 excluding VAT |
Configure product | Configure product | Configure product | Configure product |
Microtronics Engineering GmbH
Hauptstrasse 7
3244 Ruprechtshofen
Austria
Microtronics Engineering GmbH
Hauptstrasse 7
3244 Ruprechtshofen
Austria